    With the deterioration of air quality, haze worsening, air purifier into the tens of thousands of households, but the effect of air purifier how? This is the vast number of consumers and distributors need to confirm the issue. Ring Granville test center in a timely manner to seize this opportunity to deploy a large number of engineers and domestic air purifier R & D experts to study and summed up a complete set of air purifiers on the detection of pollutant removal rate.
    Shenzhen Central Granville testing center microbial testing cooperative laboratories through the China Accreditation Board accreditation (CNAS) and Guangdong Metrology Accreditation (CMA), the center issued a test report in the Asia Pacific Laboratory Accreditation Cooperation (APLAC) And the International Laboratory Accreditation Cooperation (ILAC) mutual recognition can be used as evidence of trade certification, product quality evaluation, the results of the fair data, and has the force of law.
    Test items are as follows:
    Test items
    Each file detection fee
    (yuan)
    testing base
    sample
    Quantity
    Report completion time
    Remarks
    Particle clean air volume
    (CADR)
    Solid contaminants
    (Particle size 0.3 ~ 10μm)
    -
    GB / T 18801-2008
    GB / T 18883-2002
    2 to 3 units
    20 working days
    Test space: 30m3
    Test time: 20min
    Count every 2 minutes
    PM2.5
    -
    APIAC / LM 01-2013
    Test space: 30m3
    Test time: 20min
    Count every 2 minutes
    Particulate removal rate
    Solid contaminants
    (Particle size 0.3 ~ 10μm)
    -
    GB / T 18801-2008
    GB / T 18883-2002
    Test space: 30m3
    Test time: 1h
    0h, 1h record time
    Every additional 1h 50%
    PM2.5
    -
    APIAC / LM 01-2013
    Gaseous pollutants clean air volume
    (CADR)
    formaldehyde
    -
    GB / T 18801-2008
    GB / T 18883-2002
    Test space: 30m3
    Test time: 1h
    Count every 10 minutes
    benzene
    -
    ammonia
    -
    TVOC
    -
    Organic gas removal rate
    formaldehyde
    -
    GB / T 18801-2008
    GB / T 18883-2002
    Test space: 30m3
    Test time: 1h
    0h, 1h record time
    Every additional 1h 50%
    benzene
    -
    ammonia
    -
    TVOC
    -
    Antibacterial performance
    Natural air bacteria
    -
    Sterilization Specifications - 2.1.3
    Test space: 30m3
    Test time: 1h
    0h, 1h record time
    Every additional 1h 50%
    White grapes
    Cocci
    -
    GB21551.3-
    2010
    Escherichia coli
    -
    Staphylococcus aureus
    -
    GB21551.3-
    2010
    Serratia marcescens
    -
    The amount of harmful substances released
    ozone
    -
    GB21551.3-
    2010
    1 set
    7 working days
    5cm from the outlet
    Ultraviolet
    -
    -
    TVOC
    -
    -
    PM10
    -
    -
    Power consumption
    -
    GB / T 18801-2008
    -
    Negative ion concentration
    -
    Instrumentation
    -
    noise
    -
    GB / T 18801-2008
    10 working days
    -